For smaller pipes also check out the F-Series and the new S-Series of water cut meters.
The ZelenTech ZT-100 Watercut Monitor determines the percent watercut in an oil emulsion without requiring the physical separation of the fluids. The emulsion stream is continuously monitored for capacitance and converted into percentage of water by the Watercut Monitor logic.
ZelenTech ZT-100 Watercut Meters (BS & W, OWM)
Features
Certifications
Parameter | Value |
---|---|
Principle of Operation | High Frequency Digital Capacitance |
Resolution (Low Range) | 0.001% |
Accuracy (Low Range) | 0.01% |
Resolution (High Range) | 0.05% |
Accuracy (High Range) | 0.05% |
Repeatability | 0.01% Absolute |
Max Water (Low Range) | 25% |
Max Water (High Range) | 100% |
Temp Compensation Range | >0°C – 180°C |
Parameter | Value |
---|---|
Response time | 1 sec |
Sensitivity | 0.01% |
Repeatability | 0.1% |
Output | 4-20mA + HART |
Power Supply | 24VDC (Loop Powered) |
Power Consumption | 0.66W Max |
Temperature (Media) | +150° C (250 with High Temp Option) |
Temperature (Ambient) | +60° C |
Ingress Protection | IP66 / Nema 4X & 7 |
Measurement Range | 0-25% or 0-100% |
Pressure Rating | Up to Class 1500# |
Probe entry nozzle sizes | 2 inch or 3 inch |
Line Sizes Nominal Sizes | From 12 inch to 42 inch |
Material (Standard) | 316L (Optional Duplex, Monel or other steels) |
Seals and electrical insulators | PEEK |
Parameter | Value |
---|---|
Wetted Steel Material | 316L Standard (More exotic materials available) |
Seals | PEEK |
Max. Working Pressure | Up to Class 1500# |
Max. Fluid Temperature | 180°C Standard (240°C Optional) |
Max. Ambient Temperature | 65°C |
Process Connection | ANSI, DIN |
EXD Class 1, Division 1
II 2 GD Ex d IIC T6÷T4 - Ex tD A21 IP 66/67 T85°C ÷ T135°C
Certified GOST EXD (Russia)